Volume- 3
Issue- 6
Year- 2016
Khushboo Nagar , Manish Shah MIEEE, MIE, MISLE
Neural Network has been one among few best choices for the detection of faults in electrical systems. HVDC transmission system has no doubt first choice for the long transmission of electricity all over the world. This paper presents a use of different artificial neural network for the fault detection & classification in HVDC transmission system. Here an attempt is made to cite the scholarly work done and available on renounced journals with excellent review on their work. The work is valuable and may be light house for beginners in the same field.
[1] V. sulochana, A. Francis, Dr. Andrew Tickle, “Morphology Based Radon Processed Neural network for Transmission Line Fault Detection”, International Conference on Advances in Computing, Communications and Informatics (ICACCI) IEEE, pp. 1137-1143, 2015.
[2] Y.M. Yeap, A. UKIL, “Wavelet Based Fault Analysis in HVDC System” Annual Conference of the IEEE Industrial Electronics Society IEEE, pp. 2472-2478, 2014.
[3] M. Jamil, S. Kumar Sharma & R. Singh, “Fault detection and classification in electrical power transmission system using artificial neural network” SpringerPlus, pp. 1- 13, 2015.
[4] I. Baqui, I. Zamora, J. Mazon, G. Buigues, “High impedance fault detection methodology using wavelet transform and artificial neural networks” Elsevier, pp. 1325–1333, 2011.
[5] M Ramesh, A. Jaya Laxmi, “Fault Identification in HVDC using Artificial Intelligence – Recent Trends and Perspective” IEEE, pp. 1-6, 2012.
[6] K. G. Narendra, V. K. Sood, K. Khorasani, R. Patel, “Application of a Radial Basis Function (RBF) Neural Network for Fault Diagnosis in a HVDC System” IEEE, pp. 177-183, 1998.
[7] J. Moshtagh, M. Jannati, H. R. Baghaee and E. Nasr, “A Novel Approach for Online Fault Detection in HVDC Converters” IEEE, pp. 307-311, 2008.
[8] L L Lai, F Ndeh-Che, Tejedo Chari, “Fault Identification In HVDC Systems With Neural Networks”, IEE 2nd International Conference on Advances in Power System Control, Operation and Management, December 1993, Hang Kong, pp. 231-236.
[9] M.Khodaparastan, ,A.S.Mobarake, G.B.Gharehpetian, S.H Fathi, “Smart Fault Classification in HVDC System Based on Optimal Probabilistic Neural Networks”, pp. 1-4
.[10] H. Kanoh, K. Kanemaru, M. Kaneta, M. Nishiura, “A Study on Practical Fault Location System for Power Transmission Lines using Neural Networks”, pp. 9-13.
[11] H. Etemadi, V.K. Sood, K. Khorasani, R. V. Patel, “Neural Network Based Fault Diagnosis in an HVDC System”, International Conference on Electric Utility Deregulation and Restructuring and Power Technologies, 2000, pp. 206-214.
[12] Hang Cui, Niannian Tu, “HVDC Transmission Line Fault Localization Base on RBF Neural Network with Wavelet Packet Decomposition”, IEEE International Conference on Service Systems and Service Management (ICSSSM), 2015, pp. 1-4.
[13] K.S.SuaruP, H.S.Chandrasekharalah, “Fault detection and Diagnosis of Power Converters using Artificial Neural Network”, IEEE International Conference on Power Electronics, Drives and Energy Systems for Industrial Growth, 1996, pp. 1054-1058.
[14] P.Sanjeevikumar, B. Paily, M. Basu, M. Conlon, “Classification of Fault Analysis of HVDC Systems using Artificial Neural Network”, IEEE Power Engineering Conference (UPEC), 2014, pp. 1-5.
[15] Preeti Gupta, R. N. Mahanty, “Artificial Neural Network based Fault Classifier and Locator for Transmission Line Protection”, IOSR-JEEE, Vol. 11, Issue 1 Ver. I (Jan – Feb. 2016), PP 41-53.
[16] S. A. M. Javadian, M.-R. Haghifam, N. Rezaei, “A Fault Location and Protection Scheme for Distribution Systems in presence of DG Using MLP Neural Networks”, Power & Energy Society General Meeting, 2009, IEEE, pp. 1-8.
[17] S.A.M. Javadian, A.M. Nasrabadi, M.R. Haghifam, J. Rezvantalab, “Determining Fault’s Type and Accurate Location in Distribution Systems with DG Using MLP Neural Networks”, IEEE International Conference on Clean Electrical Power, 2009 pp. 284-289.
[18] Xiangning Lin, Peng Mao , Hanli Weng, Bin Wang, Z Q Bo and A Klimek, “Study on Fault Location for High Voltage Overhead Transmission Lines Based on Neural Network System”, IEEE, International Conference on Intelligent Systems Applications to Power Systems, 2007, pp. 1-5.
[19] D.S. Gastaldello, A.N. Souza, C.C.O. Ramos, P. da Costa Junior and M.G. Zago, “Fault Location in Underground Systems Using Artificial Neural Networks and PSCAD/EMTDC”, IEEE 16th International Conference on Intelligent Engineering Systems, June 13– 15, 2012, pp. 423-427.
[20] F. Dehghani, H. Nezami, “A New Fault Location Technique on Radial Distribution Systems Using Artificial Neural Network”, 22nd International Conference on Electricity Distribution, CIRED2013, pp. 1-4.
[21] P. Bunnoon, “Fault Detection Approaches to Power System: State-of-the-Art Article Reviews for Searching a New Approach in the Future”, International Journal of Electrical and Computer Engineering (IJECE) Vol. 3, No. 4, August 2013, pp. 553~560.
[22] Kaiping Yu, Fang Yang, Hong Guo, Jinquan Xu, “Fault Diagnosis and Location of Brushless DC Motor System Based on Wavelet Transform and Artificial Neural Network”, International Conference on, Electrical Machines and Systems (ICEMS), 2010, pp. 1-5.
[23] H. Khorashadi-Zadeh, M. R. Aghaebrahimi, “A Novel Approach to Fault Classification and Fault Location for Medium Voltage Cables Based on Artificial Neural Network”, World Academy of Science, Engineering and Technology, 2008, pp. 1100-1103.
[24] Mr. Shrishail H. Patale, Prof. M. S. Potdar, “A Review on HVDC Transmission Line Protection with Different Techniques” International Journal of Engineering Sciences & Research Technology, ISSN: 2277-9655, pp. 820-824.
[25] L. L. Lal, F Wdeh-Che, Tejedo Chari, “HVDC Systems Fault Diagnosis with Neural Networks”, 1993 The European Power Electronics Association, pp. 145-150.
[26] H. Livani, C. Y. Evrenosoglu, “A single-ended fault location method for segmented HVDC transmission line”, 2013 Elsevier, Electric Power Systems Research 107 (2014) 190– 198.
[27] N. P. Srivastava, R. K. Srivastava, P. K. Vashishtha, “Fault Detection and Isolation (FDI) Via Neural Networks”, ISSN : 2248-9622, Vol. 4, Issue 1( Ver.1), January 2014, pp.81-86.
[28] S. LeBlond, R.BerthoJr., D.V.Coury, J.C.M.Vieira, “Design of protection schemes for multi-terminal HVDC systems” Elsevier 2015, pp. 966-973.
[29] Zhiqing Yao, Qun Zhang, Peng Chen, Qian Zhao, “Research on fault diagnosis for MMC-HVDC Systems”, Springer, pp. 1-7.
[30] A. Abu-Jasser, M. Ashour, “A Backpropagation Feedforward NN for Fault Detection and Classifying of Overhead Bipolar HVDC TL Using DC Measurements”, Journal of Engineering Research and Technology, Vol. 2, Issue 3, September 2015, pp. 197-202.
[31] S. Tom, J. Thomas, Ganesh M, “A Novel Algorithm for Fault Location and Identification in HVDC Transmission Lines Based on Transients”, IEEE International Conference on Emerging Research in Electronics, Computer Science and Technology – 2015, pp. 224-229.
[32] C. Venkatesh, P. Venugopal Rao, “Wavelet-ANN based Classification of HVDC Converter Faults”, International Conference on Power Systems (ICPS), 2016 IEEE, pp. 1-5.
[33] M. S. Shastrakar, M. B. Gaikwad, “Application of Artificial Neural Network In Fault Detection of HVDC Converter”, International Journal of Engineering Research & Technology (IJERT) Vol. 2 Issue 5, May – 2013 ISSN: 2278-0181.
[34] A. Swetha, P. Krishna Murthy, N. Sujatha and Y. Kiran, “A Novel Technique for the Location of Fault on A HVDC Transmission Line”, ARPN Journal of Engineering and Applied Sciences VOL. 6, NO. 11, NOV. 2011 ISSN 1819-6608, pp. 62-67.
[35] S. N. Sivanandam, S. Sumathi, S. N. Deepa, “Introduction to Neural Networks using MATLAB 6.0.”, The McGraw- Hill Companies.
[36] Sherin Tom, Jaimol Thomas, “A New Fault Identification Method for HVDC Transmission Line”, International Journal of Science and Research (IJSR) Volume 4 Issue 11, November 2015, ISSN (Online): 2319- 7064, pp. 729-734.
[37] S. M. Mangalge, S. D. Jawale, “A Review on Fault Location Techniques in Long HVDC Transmission Lines”, International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering, Vol. 5, Issue 5, May 2016, pp. 4220-4226
[38] Pannala Krishna Murthy, J.Amarnath, S. Kamakshiah, B.P. Singh, “Wavelet Transform Approach for Detection and Location of Faults in HVDC System”, Third international Conference on Industrial and Information Systems, 2008. ICIIS 2008, IEEE, pp. 1-6.
[39] L. wen-li, S. li-qun, “The Review of High Voltage DC Transmission Lines Fault Location”,International Journal of Computer, Consumer and Control (IJ3C), Vol. 3, No.4 (2014), pp. 21-28.
[40] Sourabh Mehto, Rahul Agarwal, Manish Shah, “A Comparative Study Based on PI and Fuzzy Control of Inverter fed Induction Motor Drive”, International Journal of Research (IJR) Vol-2, Issue-2 February 2015 ISSN 2348-6848, pp.75-79.
[41] Juhi Nagpal, Rahul Agarwal & Manish Shah, “A Comparative Study on Different Speed Control Methods of D.C. Drives for Electric Vehicle”, International Journal of Research (IJR) e-ISSN: 2348-6848, p- ISSN: 2348-795X Volume 2, Issue 07, July 2015, pp. 1-6.
[42] Khushboo Hardia, Neha Maithil & Manish Shah, “ Particle Swarm Optimization Applied To Economic Load Dispatch Problem”, International Journal of Research (IJR) e-ISSN: 2348-6848, p- ISSN: 2348-795X Volume 2, Issue 09, September 2015, pp. 834-843.
[43] Jyoti verma, Manish Shah, “Simulation and Analysis of H-bridge Cascade Multi level Inverter Fed Induction Motor Drive for Industrial Applications”, International Journal of Innovative Research In Electrical, Electronics, Instrumentation And Control Engineering Vol. 4, Issue 3, March 2016, pp. 17-19.
[44] Manish Shah, Rahul Agrawal, “A Review On Classical And Modern Techniques with Decision Making Tools For Load Forecasting”, International Journal of Emerging Trends in Engineering and Development Issue 3, Vol.6 (November 2013), pp. 174-184.
[45] Ritu Bhateja, Manish Shah, “A Proposed Method for Smooth Speed Control of Indirect Vector Control InverterFed Induction Motor Drive using Boost Converter Topology”, International Journal of Emerging Trends in Engineering and Development Issue 6, Vol. 5 (September 2016), pp. 1- 10.
[46] Sudeep Mohaney, Sourabh Mehto, Manish Shah, “Modeling and Optimization of Elevator Group Control System for High Rise Commercial Building”, IEEE International Conference on Computer, Communication and Control (IC4-2015).
[47] Sudeep Mohaney, Manish Shah, “Emerging Trends in Vertical Elevating System”, International Journal of Engineering and Management Research Vol.-5, Issue-1, February-2015, pp. 51-56.
M.Tech Scholar Department of Electrical Engineering VITS Indore India
No. of Downloads: 7 | No. of Views: 721
Manjeet Singh , Dr. Satish Saini.
August 2023 - Vol 10, Issue 4
Vasu Sharma, Dr. Satish Saini.
August 2023 - Vol 10, Issue 4
Mgbeike V. O, Ezechukwu O. A, Ezendiokwelu C. E, Nwoye A. N.
October 2022 - Vol 9, Issue 5